产品展示

Product Center

DG-DCL800 Residual chlorine/Total residual chlorine/chlorine dioxide sensor

DG-DCL800 Residual chlorine/Total residual chlorine/chlorine dioxide sensor

  • Category:DG-DCL800 Residual chlorine/Total residual chlorine/chlorine dioxide sensor
  • Browse number:
  • QR code:
  • Release time:2023-12-02 17:37:09
  • Product description

1. Product information

Membrane residual chlorine/total residual chlorine/chlorine dioxide electrode is a composite digital electrode using membrane amperage method. The detection part adopts special permeable membrane technology, which has the characteristics of resisting chemical interference (mainly surfactants) and reducing pH dependence. The sensor is not limited by water quality conditions, and can be applied to tap water, swimming pool, medical wastewater, sewage treatment, industrial wastewater and other environments. The sensor has high response speed, stable working performance, low cost and less maintenance, providing users with reliable and accurate data.


余氯传感器


2、Type specification

specification

Detailed information

range

0~2 mg/L,0~20 mg/L,0.5~200 mg/L

pH range

pH value: 4~9

Conductivity range

10μs/cm~50ms/cm (seawater)

Velocity of flow

In the circulation pool: 250~500mL/min

Slope drift

About -1% per month

Response time

T90: Approximately 2 minutes (90% of the measured value)

Zero calibration

It isn't necessary

Slope calibration

On the measuring device, the method of DPD-1 is used for analysis and determination

Temperature compensation

Integrated automatic temperature compensation

material

PVC-U, stainless steel, microporous hydrophilic film

Operating temperature

Measuring water temperature: 0~ 45℃ (no condensation in water); Ambient room temperature: 0~55 ℃

dimension

Diameter 25mm x length 205mm

Cable length

5 meter cable

Table 1 Technical specifications of residual chlorine/total residual chlorine/chlorine dioxide sensors

3、 the composition of the sensor

1701509656982.jpg

 

1- Electrical connection; 2- Sensor body; 3- reverse electrode; 4- working electrode; 5-O-ring 14x1.8; 6- pressure discharge port; 7- diaphragm; 8- Protective helmet; 9- Soft ring; 10- Reference electrode

Previous:None