  • Product description

1. This sensor is different from other electrodes in the market, it is manufactured with Swiss cutting-edge technology, with silicon nitride covered photopolymer film and silicon crystal semiconductor as conduction components, built-in chlorine and temperature probe, and micro-electronic components are injected and packaged by MEMS technology. As the concentration of residual chlorine or chlorine dioxide in the water sample changes, the sensor generates different current intensity, which is processed by the regulator and signal amplifier, and converted into the standard MODBUS RS485 signal.


The use of the sensor does not need to change the reagent, simple maintenance, to ensure the long-term stability of the instrument reliability and accuracy. It can be used in waterworks, rural drinking water, water stations, secondary water supply and other fields.


余氯传感器

2. Technical indicators

Product model

DG-DCL700

Measurement parameter

Residual chlorine, chlorine dioxide

Measurement method

Micro-electronic MEMS technology, special membrane structure

Measuring range

0-2mg/L/0-5mg/L

 

measure


precision


0-2mg/L

≤0.1mg/L, the absolute error is ±0.01mg/L


0.1≤X≤2mg/L, ±5% of the measured value or ±0.03mg/L (whichever is larger)


2-5mg/L

±5% of the measured value or ±0.25mg/L (whichever is larger)

Resolution (mg/L)

0.01

Polarization time

For the first time, the chlorinated water is first routed for 2 hours and then energized for half an hour

Response time

Less than 30s after polarization

Minimum conductivity

≥100μS /cm, cannot be used for ultrapure water

Operating temperature

0~45℃ (no condensation)

Temperature compensation

PT1000, built-in integration, automatic compensation

Maximum pressure

10bar

Recommended flow

≥10L/h, (in FCL-2 flow tank)

PH range

5-9. Anything below 5 will damage the membrane head

Supply voltage

12V DC±2V (customizable); Optional: 24VDC

Power dissipation

The minimum power consumption is 0.5W, the recommended power supply capacity is 1.5W

Digital communication

MODBUS RS485 communication function

Probe weight

About 210g

Probe size

See Figure 1 on page 2

Thread size

NPT 3/4

Connection mode

5-core waterproof aviation plug

Moisture-proof material

PVC and Viton® O-ring seal

Keep under warranty

2 years, membrane cap as consumable without warranty

maintenance

Membrane cap replacement cycle one year (depending on water quality)