Product Overview:
Name: Noise Recorder
Model: The QT-NL-D2 Noise Logger is a product specifically designed for real-time online monitoring and pinpointing of leaks in water supply networks. It supports wireless communication via 2G, 3G, and 4G networks, enabling remote data transmission. Data can be seamlessly sent to a web server, allowing users to log into the "Water Supply Network Online Monitoring System" via browsers on their smartphones, tablets, or computers—giving them the ability to visually and audibly inspect the noise data captured by sensors. This seamless integration of human insight and advanced technology ensures more accurate identification of leak locations.Product specifications:
Remote transmission method: 4G (All Network Compatible)Button Wake-Up: Supports Magnetic-Suction Wake-Up
Antenna: Features strong magnetic attachment and a waterproof TNC connector. Can be upgraded to a 3/5/10-meter extension antenna.
Sensor sensitivity: >1600 pc/g
On-site debugging methods: Bluetooth, WeChat Mini ProgramMeasurement range: 200m (varies depending on pipe type)
Storage Capacity: Logger sensor side features 64 MB of Flash memory, capable of storing raw noise files for up to 60 days; the server side supports unlimited data storage.
Storage content: Original sound monitoring files, sensor geographic information, sound signal analysis, and leak detection alerts
Main unit dimensions (excluding antenna): 128mm × 62mm; stainless steel device weight: 800g
Mounting method: Strong magnetic adsorption (optional anti-theft lock available)
Power supply method: Lithium battery / replaceable, with a standard lifespan of 5 years. Protection rating: IP68
Operating temperature: -30°C to 160°C (an insulated probe is required for temperatures above 60°C). The device casing is made of stainless steel, and its integrated design ensures corrosion resistance as well as reliable data acquisition and remote transmission capabilities—making it fully compliant with salt-spray testing requirements.WeChat Mini Program Interface (Bluetooth):
Configure parameters on-site, such as equipment placement and noise collection timing.
On-site data uploading and sensor function testing.Monitoring Platform:
Historical leakage status and original audio recordings
Probe Area Distribution Map
Monitoring point leakage probability display
Daily Equipment Management
Daily Business ManagementPrinciples for the placement of noise recorders:
1. Installation Location
The noise recorder should be installed on all accessible metal parts of the water supply pipes, valves, water meters, fire hydrants, air vents, and other such piping components. The surfaces in contact with the pipes must be clean.
2. Installation Spacing
The installation spacing of noise recorders decreases as the pipe diameter increases, and also diminishes with lower pipe material hardness. The lower the pipeline pressure, the closer the spacing should be; additionally, an increase in pipe fittings such as elbows and tees will also affect the optimal installation spacing. Therefore, it's essential to carefully select the appropriate spacing based on factors like pipe diameter, water pressure, and material type.
Previous page
Next page
Other Products
Jiangsu Degao Internet of Things Technology Co., Ltd.
Consulting
Recruitment
Address
No. 158, Xinsheng Road, Nantong, Jiangsu, Maipu Technology Park

Subscription Number

Service Number

Mobile phone QR code
Copyright © 2025 Jiangsu Degao Internet of Things Technology Co., Ltd.
Powered by www.300.cn | Tag |