DGS-1000 series pipe section electromagnetic flowmeter is an intelligent electromagnetic flowmeter developed by our company using unique patented technology and combining the most advanced technology at home and abroad. The product has high measurement accuracy, stability, and reliability; In the process of product structure, material selection, manufacturing process, production assembly, and factory testing, eighteen core process steps are meticulous and strict.
Degao Environment's Intelligent Industry 4.0 production control system and the national blind spot free and considerate after-sales service system provide systematic solutions for various types of customers.
1. Main applications
● Zoning metering, secondary water supply
● Large user trade settlement
● Food hygiene industry
● Chemical Industry
● Sewage industry
● Biopharmaceutical industry
2. Overall dimensions and nominal pressure
3. Technical features
4. Gds-1000 series pipe segment electromagnetic flowmeter advantages
◆ High accuracy: ·0.2% ·0.3% ·0.5%;
◆ High reliability;
◆ DGS-1000 Special food grade lining made by Degao Company
◆ With pressure measurement, synchronous acquisition with flow, synchronous analysis; core circuit board adopts military quality low noise, high precision components, can maintain high precision measurement at low flow rate for a long time;
◆ It can be measured in both directions, applicable to multi-channel water inlet cells;
◆ Support 0.005m/s ultra-low flow rate measurement (specially customized for zone measurement), small flow measurement is excellent, is the preferred product for high-end trade settlement;
◆ Super anti-interference: unique two-stage shielding technology, can be installed pump room;
◆ Lithium battery life is long;
◆ Optional meter reading mode: ·4G · NB-IoT ·RS-485;
◆ Meter reading frequency can be customized according to customer requirements;
◆ Every change is reported: voltage, electricity, water overruns, sudden changes, non-full tube can be changed alarm;
◆ Overall diving design;
5. Main technical parameters
accuracy | 0.2级、0.3级、0.5级 |
repeatability | 0.06%、0.09%、0.15% |
Measuring fluid | Conducting fluid |
Electric conductivity | ≥10μS/cm |
Measured velocity range | 0.3-12m/s |
Output signal | The standard output signal is pulse/frequency output, and the output available is 4~20mA, isolated RS485 digital communication interface |
Power supply | 220VAC/24VDC/ 3.6VDC Lithium battery/Lithium battery + Solar battery/Lithium battery +220VAC |
Sensor aperture | DN15-DN3000 |
Working pressure | DN15-DN80 (4. 0 MPa) , DN100-DN150 (1.6 MPa) , DN200-DN1000 ( 1. 0MPa),DN1200-DN3000(0.6MPa) |
Ambient temperature | -25℃~60℃, humidity is 5%~90% |
Operating medium temperature | ≤70℃ (Neoprene CR, Polyurethane rubber PU), ≤120℃ (polytetrafluoroethylene F4 (PTFE), polyperfluorinated ethylene propylene F46 (FEP), ceramics, etc.) |
Class of protection | IP67/IP68 |
Electrode structure | Standard electrode: 2 electrodes (≤DN700); 4 electrodes (≥DN800) |
Electrode material | Selected according to the measured medium, there are 316L stainless steel, Hastelloy B, Hastelloy C, tantalum, titanium, platinum, ceramics, etc |
shell | Painted steel or stainless steel case |
Installation form | A type sensor and transducer are mounted together; Separate sensor and converter (with 5m standard cable) |
6. Measuring range of tube segment electromagnetic flowmeter